DXR 240

REFRIGERANT GAS LEAK DETECTOR

HFC, HFO, HC & H2/N2 TRACER GAS (FORMING GAS) & NIDRON

The DXR 240 is a portable leak detector for HFC, HFO and HC refrigerants and H2/N2 tracer gas, designed for leak detection by sniffing in maintenance and workshop use. Its OLED graphic display, combined with a progressive audible signal, guides the operator to the leak point, while the LED built into the top of the housing lights up hard-to-reach areas.

In the same range:

Selective for H2/N2 tracer gas (Nidron), the DXH 240 has 4 sensitivity positions and a Track mode. CO2 / R744 is detected with the IRD 92 E, which uses infrared technology and has a 4-digit digital display. Finally, for leak testing on production lines or in expert analysis, the MTD 920 calibrates itself automatically and displays an estimated leak rate.

Accessories:

The sensitivity of the DXR 240 can be checked before use with the FT 92-T test leak (5 g/yr, in R134a, R1234ze or R1234yf), supplied with a verification certificate. For certification in accordance with the EN 14624 standard, the FCE 99M-PVS-R EN 14624 calibrated leak is supplied with a calibration certificate.
  • Leak detector for refrigerant gases and H2/N2 tracer gas.
  • Gas type selection.
  • Graphic display with bar graph for efficient leak pinpointing.

3 sensitivity positions: HI, MED, LOW.

2 detection cells available:

  • Detection cell for all refrigerant gases HFC, HFO, HC (R1234ze, R134a, R404A, R407C, R410A, R32… R290, R600a)
  • Selective detection cell for the H2/N2 tracer gas mixture.
Find this product here: Find our gas leak detectors on HelloPro - B2B network
Functions

Gas type selector HFC, HFO, HC, H2/N2.

3 sensitivity positions HI, MED, LOW.

Automatic zero on the ambient atmosphere.

Contamination-saturation indication.

LED light at the top of the housing to illuminate dark detection areas.

Replaceable and interchangeable detection cell.

DisplayGraphic display with bar graph and progressive audible signal.
CellElectrochemical.
Detected gases

Cell for all refrigerant gases: HFC (R134a, R404A, R407C, R410A, R32…), HFO (R1234ze, R1234yf…), R600a, R290, H2/N2.

Specific tracer gas cell: H2/N2, Nidron.

Sensitivity

HFC, HFO: 1 g/yr.

R600a & R290: 0.5 g/yr.

H2/N2 tracer gas mixture, Nidron: 1×10⁻⁵ cc/s [approx. 1 g/yr refrigerant equivalent].

Battery life8 h
Power supply

Built-in rechargeable batteries. Charging time around 12 hours.

USB-C charging port.

Delivered with

Supplied complete in a carrying case with mains charger and user manual.

OptionNone

Usage tips

  • Search method: as refrigerants are heavier than air, the leak search starts above the fittings or brazed joints to be tested and works downwards, so that no gas is detected before the source of the leak is reached. With H2/N2 tracer gas, hydrogen, which is lighter than air, rises: the search is therefore carried out from below, working upwards.
  • Leak confirmation: with its automatic zero, the detector only reacts to rapid changes in gas concentration; if the probe is held still on the leak, the signal gradually decreases. To confirm the leak, simply move the probe away from the leak point, wait for the signal to return to zero, then place it back at the same spot.
  • Preparing the area: degreasers, solvents and cleaning agents, as well as vapours from glues, paints or expanded foams, can damage the detection cell and cause false alarms. The area must therefore be clean and dry before searching for leaks on a system.
  • After detecting a large leak: before resuming the search at high sensitivity, the probe must be returned to clean air until the signal has returned to zero.