DXH 240
TRACER GAS LEAK DETECTOR
FORMING GAS, N2/H2 TRACER GAS & NIDRON
The DXH 240 is a portable gas leak detector for the detection of hydrogenated nitrogen gas (forming gas), nidron or N2/H2 tracer gas. Designed for leak testing by sniffing at atmospheric pressure.In the same range:
For HFC, HFO, HC refrigerant gas detection in addition to H2/N2, the DXR 240 offers 3 sensitivity positions. For high-sensitivity tightness control on production lines or expert use, the MTD 920 provides automatic calibration on a calibrated leak and displays the estimated leak rate value.
Accessories:
For quick DXH 240 sensitivity verification, use the FT 92-T test leak (equivalent to 5 g/year, for H2/N2 mixture on request). For verification with a specific leak rate, use the FCH 99M-PVA-R150 adjustable calibrated leak with its built-in tank, delivered with a pressure/flow curve.
- Leak detector for the detection of N2/H2 tracer gas & Nidron.
- 2 Détection modes.
- Graphical display with ramp allowing efficient localization of leak points.
2 Detection modes:
- Detection mode with auto-zero.
- Track mode for leak location.
4 sensitivity positions.
Detection sensor type :
- Selective detection sensor for N2/H2 tracer gas mixture.
| Functions | 4 sensitivity positions. 2 detection modes: Detection Mode and Track Mode. Contamination-saturation indication. Illuminating LED at the top of the box to illuminate dark detection areas. Replaceable and interchangeable detection cell. |
| Display | Graphic display with ramp and progressive sound signal. |
| Sensor | Electrochemical. |
| Detected gases | Specific tracer gas sensor: N2/H2, NIDRON. |
| Sensitivity | 1.10-5 cc/s for H2/N2 tracer mixture [equivalent to approx. 1 g/year of refrigerant gas] |
| Autonomy | 8h |
| Power supply | Built-in rechargeable batteries. Charging time around 12 hours. USB Type C charging socket. |
| Delivered with | Detector delivered complete in transport case with mains charger and instructions for use. |
| Option | n/a |