<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Concentration Meters, Catharometer | SAPRE</title>
	<atom:link href="https://www.sapre.fr/en/produits/concentration-meters/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sapre.fr/en/produits/concentration-meters/</link>
	<description>Conception et Fabrication de détecteurs de fuite de gaz</description>
	<lastBuildDate>Mon, 27 Apr 2026 20:14:49 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.5</generator>

<image>
	<url>https://www.sapre.fr/wp-content/uploads/2015/03/logo250-60x60.png</url>
	<title>Concentration Meters, Catharometer | SAPRE</title>
	<link>https://www.sapre.fr/en/produits/concentration-meters/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TG DISPLAY</title>
		<link>https://www.sapre.fr/en/products/tg-display/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 27 Jan 2020 10:16:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/?post_type=portfolio&#038;p=10456</guid>

					<description><![CDATA[<p>TG DISPLAY HELIUM &#38; ARGON CONCENTRATION METER HELIUM &#38; ARGON CATHAROMETER The TG DISPLAY is a catharometer-type concentration meter for Helium and Argon, mainly used for so-called “under-enclosure” tightness control. In the same range: For Helium or Argon concentration measurement in a fixed station with sampling or continuous measurement, the MCB 97T3 is the 19&#8243; [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/en/products/tg-display/">TG DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="10456" class="elementor elementor-10456" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-e852df2 e-flex e-con-boxed e-con e-parent" data-id="e852df2" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-8173126 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="8173126" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>TG DISPLAY</h1>
<h2>HELIUM &amp; ARGON CONCENTRATION METER</h2>
<h2>HELIUM &amp; ARGON CATHAROMETER</h2>
The TG DISPLAY is a catharometer-type concentration meter for Helium and Argon, mainly used for so-called “under-enclosure” tightness control.

<h3>In the same range:</h3>
<p>For Helium or Argon concentration measurement in a fixed station with sampling or continuous measurement, the <a href="https://www.sapre.fr/en/products/mcb-97t3/">MCB 97T3</a> is the 19&#8243; rack catharometer concentration meter with ATEX cell, 0/1V analog output and extended measurement range from 0.1% to 100%. For Helium or Argon leak detection and localization (rather than concentration measurement), the <a href="https://www.sapre.fr/en/products/tg-expert/">TG EXPERT</a> is the suitable catharometer leak detector.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-bac677e e-flex e-con-boxed e-con e-parent" data-id="bac677e" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-3d941e2 e-con-full e-flex e-con e-child" data-id="3d941e2" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-e3221ac elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="e3221ac" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 1"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="e3221ac" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTA1MSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL3RnLWRpc3BsYXkuanBnIiwic2xpZGVzaG93IjoiZTMyMjFhYyJ9" href="https://www.sapre.fr/wp-content/uploads/2024/04/tg-display.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/tg-display-768x768.jpg" alt="TG DISPLAY mesureur de concentration Hélium et Argon catharomètre - SAPRE" /></figure></a></div>			</div>
					</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-fca0c44 e-con-full e-flex e-con e-child" data-id="fca0c44" data-element_type="container">
				<div class="elementor-element elementor-element-00228a3 elementor-widget elementor-widget-text-editor" data-id="00228a3" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<div class="elementor-element elementor-element-00228a3 elementor-widget elementor-widget-text-editor" data-id="00228a3" data-element_type="widget" data-widget_type="text-editor.default"><div class="elementor-widget-container"><ul><li>Concentration reading from 1% to 100%.</li><li>Measuring cell with unsaturable thermal conductivity.</li><li>3-digit digital display.</li></ul><p><strong>2 Calibrations :</strong></p><ul><li>Pre-calibrated device for helium and argon with selection button.</li><li>Other calibrations possible on request.</li></ul></div></div><div class="elementor-element elementor-element-4cee1b6 elementor-widget elementor-widget-button" data-id="4cee1b6" data-element_type="widget" data-widget_type="button.default"> </div>						</div>
				</div>
				<div class="elementor-element elementor-element-4cee1b6 elementor-widget elementor-widget-button" data-id="4cee1b6" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/en/information-request/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">INFORMATION REQUEST</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-24efe10 elementor-widget elementor-widget-text-editor" data-id="24efe10" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							Find this product here:
<a href="https://www.hellopro.fr/sapre-127893-societe.html#presentation" target="_blank" rel="noopener"><img decoding="async" class="alignnone wp-image-9313 size-full" src="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png" alt="Find our gas leak detectors on HelloPro - B2B network" width="150" srcset="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png 200w, https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t-18x6.png 18w" sizes="(max-width: 200px) 100vw, 200px" /></a>						</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-ee03d0e e-flex e-con-boxed e-con e-parent" data-id="ee03d0e" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-b4ff309 elementor-widget elementor-widget-text-editor" data-id="b4ff309" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Functions</strong></td><td style="text-align: left;"><p>Helium/Argon gas selector.</p><p>Manual zero by push button.</p></td></tr><tr><td style="text-align: left;"><strong>Display</strong></td><td style="text-align: left;">3-digit digital display.</td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Sensor</strong></td><td style="text-align: left;">Measuring cell with unsaturable thermal conductivity.</td></tr><tr><td style="text-align: left;"><strong>Detected gases</strong></td><td style="text-align: left;">Helium, Argon, other gases on request.</td></tr><tr><td style="text-align: left;"><strong>Sensitivity</strong></td><td style="text-align: left;">Direct measurement of gas concentration from 1% to 100%.</td></tr><tr><td style="text-align: left;"><strong>Autonomy</strong></td><td style="text-align: left;">6-8h</td></tr><tr><td style="text-align: left;"><strong>Power supply</strong></td><td style="text-align: left;">Built-in rechargeable batteries. Charging time around 12 hours.</td></tr><tr><td style="text-align: left;"><strong>Delivered with</strong></td><td style="text-align: left;">Detector delivered complete in transport case with mains charger and instructions for use.</td></tr><tr><td style="text-align: left;"><strong>Option</strong></td><td style="text-align: left;">n/a</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/en/products/tg-display/">TG DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OX DISPLAY</title>
		<link>https://www.sapre.fr/en/products/ox-display/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 27 Jan 2020 10:01:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/?post_type=portfolio&#038;p=10458</guid>

					<description><![CDATA[<p>OX DISPLAY OXYGEN CONCENTRATION METER The OX DISPLAY is an Oxygen concentration meter, mainly used for measuring oxygen concentration in soldering or passivation applications. In the same range: For Helium or Argon concentration measurement mainly used in under-enclosure tightness testing, the TG DISPLAY is the dedicated catharometer concentration meter, with a measurement range from 1% [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/en/products/ox-display/">OX DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="10458" class="elementor elementor-10458" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-e852df2 e-flex e-con-boxed e-con e-parent" data-id="e852df2" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-8173126 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="8173126" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>OX DISPLAY</h1>
<h2>OXYGEN CONCENTRATION METER</h2>
The OX DISPLAY is an Oxygen concentration meter, mainly used for measuring oxygen concentration in soldering or passivation applications.

<h3>In the same range:</h3>
<p>For Helium or Argon concentration measurement mainly used in under-enclosure tightness testing, the <a href="https://www.sapre.fr/en/products/tg-display/">TG DISPLAY</a> is the dedicated catharometer concentration meter, with a measurement range from 1% to 100%.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-bac677e e-flex e-con-boxed e-con e-parent" data-id="bac677e" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-3d941e2 e-con-full e-flex e-con e-child" data-id="3d941e2" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-e3221ac elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="e3221ac" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="e3221ac" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTgzNywidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyMFwvMDFcL294LWRpc3BsYXkuanBnIiwic2xpZGVzaG93IjoiZTMyMjFhYyJ9" href="https://www.sapre.fr/wp-content/uploads/2020/01/ox-display.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2020/01/ox-display-768x768.jpg" alt="OX DISPLAY mesureur de concentration oxygène pour brasure et passivation - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="e3221ac" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTgzOSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL294LWRpc3BsYXlfcGlwZS5qcGciLCJzbGlkZXNob3ciOiJlMzIyMWFjIn0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/ox-display_pipe.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/ox-display_pipe-768x768.jpg" alt="" /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-left" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z"></path></svg>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-right" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z"></path></svg>					</div>
				
									</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-fca0c44 e-con-full e-flex e-con e-child" data-id="fca0c44" data-element_type="container">
				<div class="elementor-element elementor-element-00228a3 elementor-widget elementor-widget-text-editor" data-id="00228a3" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Concentration reading from 0.01% to 25.0%.</li><li>Displays oxygen level up to 100 ppm.</li><li>3-digit digital display.</li></ul><p><strong>Automatic compensation :</strong></p><ul><li>Automatic compensation of sensor sensitivity based on ambient temperature.</li></ul><p><strong>2 Sampling tips :</strong></p><ul><li>Inlet/outlet push-in tip for supply tube connection.</li><li>Rigid needle type pipe tip.</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-4cee1b6 elementor-widget elementor-widget-button" data-id="4cee1b6" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/en/information-request/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">INFORMATION REQUEST</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-24efe10 elementor-widget elementor-widget-text-editor" data-id="24efe10" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							Find this product here:
<a href="https://www.hellopro.fr/sapre-127893-societe.html#presentation" target="_blank" rel="noopener"><img decoding="async" class="alignnone wp-image-9313 size-full" src="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png" alt="Find our gas leak detectors on HelloPro - B2B network" width="150" srcset="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png 200w, https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t-18x6.png 18w" sizes="(max-width: 200px) 100vw, 200px" /></a>						</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-ee03d0e e-flex e-con-boxed e-con e-parent" data-id="ee03d0e" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-b4ff309 elementor-widget elementor-widget-text-editor" data-id="b4ff309" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Functions</strong></td><td style="text-align: left;"><p>Automatic compensation.</p><p>Calibration by manual zero on ambient air 20.9%.</p><p>Interchangeable sampling tips.</p></td></tr><tr><td style="text-align: left;"><strong>Display</strong></td><td style="text-align: left;">3-digit digital display.</td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Sensor</strong></td><td style="text-align: left;">Electrochemical oxygen cell, lifespan of approximately 2 years.</td></tr><tr><td style="text-align: left;"><strong>Detected gases</strong></td><td style="text-align: left;">O2 / Oxygen.</td></tr><tr><td style="text-align: left;"><strong>Sensitivity</strong></td><td style="text-align: left;"><p>Direct measurement of gas concentration from 0.01% to 25.0%.</p><p>Displays oxygen level up to 100 ppm (0.01%).</p></td></tr><tr><td style="text-align: left;"><strong>Autonomy</strong></td><td style="text-align: left;">6-8h</td></tr><tr><td style="text-align: left;"><strong>Power supply</strong></td><td style="text-align: left;">Built-in rechargeable batteries. Charging time around 12 hours.</td></tr><tr><td style="text-align: left;"><strong>Delivered with</strong></td><td style="text-align: left;">Detector delivered complete in transport case with mains charger and instructions for use.</td></tr><tr><td style="text-align: left;"><strong>Option</strong></td><td style="text-align: left;">n/a</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/en/products/ox-display/">OX DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB 97T3</title>
		<link>https://www.sapre.fr/en/products/mcb-97t3/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 27 Jan 2020 09:31:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/?post_type=portfolio&#038;p=10460</guid>

					<description><![CDATA[<p>MCB 97T3 HELIUM &#38; ARGON CONCENTRATION METER HELIUM &#38; ARGON CATHAROMETER The MCB 97T3 is a concentration meter, catharometer type, for Helium and Argon, measuring the concentrations of binary or pseudo-binary gas mixtures from 0.1% to 100%. In the same range: For portable, one-off Helium or Argon concentration measurement, the TG DISPLAY is the dedicated [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/en/products/mcb-97t3/">MCB 97T3</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="10460" class="elementor elementor-10460" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-6e1a2b8 e-flex e-con-boxed e-con e-parent" data-id="6e1a2b8" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-508674c elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="508674c" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>MCB 97T3</h1>
<h2>HELIUM &amp; ARGON CONCENTRATION METER</h2>
<h2>HELIUM &amp; ARGON CATHAROMETER</h2>
The MCB 97T3 is a concentration meter, catharometer type, for Helium and Argon, measuring the concentrations of binary or pseudo-binary gas mixtures from 0.1% to 100%.

<h3>In the same range:</h3>
<p>For portable, one-off Helium or Argon concentration measurement, the <a href="https://www.sapre.fr/en/products/tg-display/">TG DISPLAY</a> is the dedicated portable catharometer concentration meter, mainly used for under-enclosure tightness testing.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-a22ad72 e-flex e-con-boxed e-con e-parent" data-id="a22ad72" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-91a89cd e-con-full e-flex e-con e-child" data-id="91a89cd" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-9e79055 elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="9e79055" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="9e79055" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTA1NSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL21jYjk3dDMtMS5qcGciLCJzbGlkZXNob3ciOiI5ZTc5MDU1In0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-1.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-1-768x768.jpg" alt="MCB 97T3 mesureur catharomètre Hélium Argon rack 19 pouces - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="9e79055" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTA1NiwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL21jYjk3dDMtMi5qcGciLCJzbGlkZXNob3ciOiI5ZTc5MDU1In0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-2.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-2-768x768.jpg" alt="" /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-left" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z"></path></svg>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-right" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z"></path></svg>					</div>
				
									</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d89a1ba e-con-full e-flex e-con e-child" data-id="d89a1ba" data-element_type="container">
				<div class="elementor-element elementor-element-2a2700d elementor-widget elementor-widget-text-editor" data-id="2a2700d" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Concentration reading from 0.1% to 100%.</li><li>ATEX unsaturable thermal conductivity measuring cell.</li><li>Rack 19″ 3U, 21TE</li><li>3-digit digital display.</li></ul><p><strong>Calibration :</strong></p><ul><li>Device pre-calibrated for helium.</li><li>Other calibrations possible on request.</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-cb11727 elementor-widget elementor-widget-button" data-id="cb11727" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/en/information-request/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">INFORMATION REQUEST</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-3ec9315 e-flex e-con-boxed e-con e-parent" data-id="3ec9315" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-ea1471b elementor-widget elementor-widget-text-editor" data-id="ea1471b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Functions</strong></td><td style="text-align: left;"><p>19’’ rack drawer, 3U, 21TE.</p><p>2 types of cell assembly (depending on version) :</p><ul><li>Remote cell connected by cable with gas circulation by natural convection.</li><li>Cell fixed to the rear of the box with cap and end caps for connecting tubes for gas supply.</li></ul></td></tr><tr><td style="text-align: left;"><strong>Display</strong></td><td style="text-align: left;"><p>3-digit digital display.</p><p>Analog output 0/1 volt.</p><p>2 setpoint relays [+] and [-] with adjustable threshold, with T/R contact outputs.</p></td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Sensor</strong></td><td style="text-align: left;">ATEX unsaturable thermal conductivity cell.</td></tr><tr><td style="text-align: left;"><strong>Detected gases</strong></td><td style="text-align: left;">Factory calibration on Helium gas, other gas on request (Argon, etc.)</td></tr><tr><td style="text-align: left;"><strong>Sensitivity</strong></td><td style="text-align: left;">Concentration reading from 0.1% to 100%.</td></tr><tr><td style="text-align: left;"><strong>Autonomy</strong></td><td style="text-align: left;">n/a</td></tr><tr><td style="text-align: left;"><strong>Power supply</strong></td><td style="text-align: left;">Mains supply 220v, 50/60 Hz.</td></tr><tr><td style="text-align: left;"><strong>Delivered with</strong></td><td style="text-align: left;">Detector delivered complete with pluggable screw terminal blocks and instructions for use.</td></tr><tr><td style="text-align: left;"><strong>Option</strong></td><td style="text-align: left;">n/a</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/en/products/mcb-97t3/">MCB 97T3</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
