<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Mesureur de Concentration, Catharomètre | SAPRE</title>
	<atom:link href="https://www.sapre.fr/produits/mesureur-de-concentration/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sapre.fr/produits/mesureur-de-concentration/</link>
	<description>Conception et Fabrication de détecteurs de fuite de gaz</description>
	<lastBuildDate>Mon, 27 Apr 2026 20:12:57 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.5</generator>

<image>
	<url>https://www.sapre.fr/wp-content/uploads/2015/03/logo250-60x60.png</url>
	<title>Mesureur de Concentration, Catharomètre | SAPRE</title>
	<link>https://www.sapre.fr/produits/mesureur-de-concentration/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TG DISPLAY</title>
		<link>https://www.sapre.fr/produits/tgdisplay/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 27 Jan 2020 10:15:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/produit/tg-2005-2/</guid>

					<description><![CDATA[<p>TG DISPLAY MESUREUR DE CONCENTRATION HÉLIUM &#38; ARGON CATHAROMÈTRE HÉLIUM &#38; ARGON Le TG DISPLAY est un mesureur de concentration type catharomètre pour l&#8217;Hélium et l&#8217;Argon, principalement utilisé pour les contrôles d’étanchéité dit « sous enveloppe ». Dans la même gamme : Pour une mesure de concentration Hélium ou Argon en station fixe avec un [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/produits/tgdisplay/">TG DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="6259" class="elementor elementor-6259" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-e852df2 e-flex e-con-boxed e-con e-parent" data-id="e852df2" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-8173126 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="8173126" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>TG DISPLAY</h1>
<h2>MESUREUR DE CONCENTRATION HÉLIUM &amp; ARGON</h2>
<h2>CATHAROMÈTRE HÉLIUM &amp; ARGON</h2>
Le TG DISPLAY est un mesureur de concentration type catharomètre pour l&rsquo;Hélium et l&rsquo;Argon, principalement utilisé pour les contrôles d’étanchéité dit « sous enveloppe ».

<h3>Dans la même gamme :</h3>
<p>Pour une mesure de concentration Hélium ou Argon en station fixe avec un échantillonnage ou mesure en continue, le <a href="https://www.sapre.fr/produits/mcb97/">MCB 97T3</a> est le mesureur catharomètre rack 19&Prime; avec cellule ATEX, sortie analogique 0/1V et plage de mesure étendue de 0,1% à 100%. Pour la détection et localisation de fuites Hélium ou Argon (et non la mesure de concentration), le <a href="https://www.sapre.fr/produits/tgexpert/">TG EXPERT</a> est le détecteur catharomètre adapté.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-bac677e e-flex e-con-boxed e-con e-parent" data-id="bac677e" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-3d941e2 e-con-full e-flex e-con e-child" data-id="3d941e2" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-e3221ac elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="e3221ac" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 sur 1"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="e3221ac" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTA1MSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL3RnLWRpc3BsYXkuanBnIiwic2xpZGVzaG93IjoiZTMyMjFhYyJ9" href="https://www.sapre.fr/wp-content/uploads/2024/04/tg-display.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/tg-display-768x768.jpg" alt="TG DISPLAY mesureur de concentration Hélium et Argon catharomètre - SAPRE" /></figure></a></div>			</div>
					</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-fca0c44 e-con-full e-flex e-con e-child" data-id="fca0c44" data-element_type="container">
				<div class="elementor-element elementor-element-00228a3 elementor-widget elementor-widget-text-editor" data-id="00228a3" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Lecture de concentration de 1% à 100%.</li><li>Cellule de mesure à conductivité thermique insaturable.</li><li>Afficheur digital 3 chiffres.</li></ul><p><strong>2 Calibrations :</strong></p><ul><li>Appareil pré-calibré pour l&rsquo;hélium et l&rsquo;argon avec bouton de sélection.</li><li>Autres calibrations possibles sur demande.</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-4cee1b6 elementor-widget elementor-widget-button" data-id="4cee1b6" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/demande-dinformations/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">DEMANDE D'INFORMATIONS</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-24efe10 elementor-widget elementor-widget-text-editor" data-id="24efe10" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							Retrouvez ce produit sur :
<a href="https://www.hellopro.fr/sapre-127893-societe.html#presentation" target="_blank" rel="noopener"><img decoding="async" class="alignnone wp-image-9313 size-full" src="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png" alt="Retrouvez nos détecteurs de fuite de gaz sur HelloPro - réseau B2B" width="150" srcset="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png 200w, https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t-18x6.png 18w" sizes="(max-width: 200px) 100vw, 200px" /></a>						</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-ee03d0e e-flex e-con-boxed e-con e-parent" data-id="ee03d0e" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-b4ff309 elementor-widget elementor-widget-text-editor" data-id="b4ff309" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Fonctions</strong></td><td style="text-align: left;"><p>Sélecteur de gaz Hélium / Argon.</p><p>Zéro manuel par bouton poussoir.</p></td></tr><tr><td style="text-align: left;"><strong>Affichage</strong></td><td style="text-align: left;">Afficheur digital 3 chiffres.</td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Cellule</strong></td><td style="text-align: left;">Cellule de mesure à conductivité thermique insaturable.</td></tr><tr><td style="text-align: left;"><strong>Gaz détectés</strong></td><td style="text-align: left;">Hélium, Argon, autres gaz sur demande.</td></tr><tr><td style="text-align: left;"><strong>Sensibilité</strong></td><td style="text-align: left;">Mesure directe de la concentration de gaz de 1% à 100%.</td></tr><tr><td style="text-align: left;"><strong>Autonomie</strong></td><td style="text-align: left;">6-8h</td></tr><tr><td style="text-align: left;"><strong>Alimentation</strong></td><td style="text-align: left;">Batteries rechargeables incorporées. Temps de recharge 12h environs.</td></tr><tr><td style="text-align: left;"><strong>Livré avec</strong></td><td style="text-align: left;">Détecteur livré complet en valise de transport avec chargeur secteur et notice d’emploi.</td></tr><tr><td style="text-align: left;"><strong>Option</strong></td><td style="text-align: left;">n/a</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/produits/tgdisplay/">TG DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OX DISPLAY</title>
		<link>https://www.sapre.fr/produits/oxdisplay/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 27 Jan 2020 10:00:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/nos-produits/tgdisplay-copy/</guid>

					<description><![CDATA[<p>OX DISPLAY MESUREUR DE CONCENTRATION OXYGÈNE L&#8217;OX DISPLAY est un mesureur de concentration  pour l&#8217;Oxygène, principalement utilisé pour la mesure de la concentration en oxygène dans les applications de brasure ou de passivation. Dans la même gamme : Pour la mesure de concentration d&#8217;Hélium ou d&#8217;Argon principalement en technique de détection « sous enveloppe », [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/produits/oxdisplay/">OX DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="9835" class="elementor elementor-9835" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-e852df2 e-flex e-con-boxed e-con e-parent" data-id="e852df2" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-8173126 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="8173126" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>OX DISPLAY</h1>
<h2>MESUREUR DE CONCENTRATION OXYGÈNE</h2>
L&rsquo;OX DISPLAY est un mesureur de concentration  pour l&rsquo;Oxygène, principalement utilisé pour la mesure de la concentration en oxygène dans les applications de brasure ou de passivation.

<h3>Dans la même gamme :</h3>
<p>Pour la mesure de concentration d&rsquo;Hélium ou d&rsquo;Argon principalement en technique de détection « sous enveloppe », le <a href="https://www.sapre.fr/produits/tgdisplay/">TG DISPLAY</a> est le mesureur catharomètre dédié, avec une plage de mesure de 1% à 100%.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-bac677e e-flex e-con-boxed e-con e-parent" data-id="bac677e" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-3d941e2 e-con-full e-flex e-con e-child" data-id="3d941e2" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-e3221ac elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="e3221ac" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 sur 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="e3221ac" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTgzNywidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyMFwvMDFcL294LWRpc3BsYXkuanBnIiwic2xpZGVzaG93IjoiZTMyMjFhYyJ9" href="https://www.sapre.fr/wp-content/uploads/2020/01/ox-display.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2020/01/ox-display-768x768.jpg" alt="OX DISPLAY mesureur de concentration oxygène pour brasure et passivation - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 sur 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="e3221ac" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTgzOSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL294LWRpc3BsYXlfcGlwZS5qcGciLCJzbGlkZXNob3ciOiJlMzIyMWFjIn0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/ox-display_pipe.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/ox-display_pipe-768x768.jpg" alt="" /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-left" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z"></path></svg>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-right" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z"></path></svg>					</div>
				
									</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-fca0c44 e-con-full e-flex e-con e-child" data-id="fca0c44" data-element_type="container">
				<div class="elementor-element elementor-element-00228a3 elementor-widget elementor-widget-text-editor" data-id="00228a3" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Lecture de concentration de 0.01% à 25.0%.</li><li>Affiche le niveau d’oxygène jusqu’à 100 ppm.</li><li>Afficheur digital 3 chiffres.</li></ul><p><strong>Compensation automatique :</strong></p><ul><li>Compensation automatique de la sensibilité du capteur en fonction de la température ambiante.</li></ul><p><strong>2 Embouts de prélèvement :</strong></p><ul><li>Embout push-in entrée/sortie pour raccordement de tube d’alimentation.</li><li>Embout pipe rigide type aiguille.</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-4cee1b6 elementor-widget elementor-widget-button" data-id="4cee1b6" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/demande-dinformations/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">DEMANDE D'INFORMATIONS</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-24efe10 elementor-widget elementor-widget-text-editor" data-id="24efe10" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							Retrouvez ce produit sur :
<a href="https://www.hellopro.fr/sapre-127893-societe.html#presentation" target="_blank" rel="noopener"><img decoding="async" class="alignnone wp-image-9313 size-full" src="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png" alt="Retrouvez nos détecteurs de fuite de gaz sur HelloPro - réseau B2B" width="150" srcset="https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t.png 200w, https://www.sapre.fr/wp-content/uploads/2024/04/hellopro-t-18x6.png 18w" sizes="(max-width: 200px) 100vw, 200px" /></a>						</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-ee03d0e e-flex e-con-boxed e-con e-parent" data-id="ee03d0e" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-b4ff309 elementor-widget elementor-widget-text-editor" data-id="b4ff309" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Fonctions</strong></td><td style="text-align: left;"><p>Compensation automatique.</p><p>Calibration par Zéro manuel sur air ambiant 20.9%.</p><p>Embouts de prélèvement interchangeables.</p></td></tr><tr><td style="text-align: left;"><strong>Affichage</strong></td><td style="text-align: left;">Afficheur digital 3 chiffres.</td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Cellule</strong></td><td style="text-align: left;">Cellule oxygène électrochimique, durée de vie d’environ 2 ans.</td></tr><tr><td style="text-align: left;"><strong>Gaz détectés</strong></td><td style="text-align: left;">O2 / Oxygène.</td></tr><tr><td style="text-align: left;"><strong>Sensibilité</strong></td><td style="text-align: left;"><p>Mesure directe de la concentration de gaz de 0.01% à 25.0%.</p><p>Affiche le niveau d’oxygène jusqu’à 100 ppm (0,01%).</p></td></tr><tr><td style="text-align: left;"><strong>Autonomie</strong></td><td style="text-align: left;">6-8h</td></tr><tr><td style="text-align: left;"><strong>Alimentation</strong></td><td style="text-align: left;">Batteries rechargeables incorporées. Temps de recharge 12h environs.</td></tr><tr><td style="text-align: left;"><strong>Livré avec</strong></td><td style="text-align: left;">Détecteur livré complet en valise de transport avec chargeur secteur et notice d’emploi.</td></tr><tr><td style="text-align: left;"><strong>Option</strong></td><td style="text-align: left;">n/a</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/produits/oxdisplay/">OX DISPLAY</a> est apparu en premier sur <a href="https://www.sapre.fr">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB 97T3</title>
		<link>https://www.sapre.fr/produits/mcb97/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 27 Jan 2020 09:30:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/produit/tg-2012-c-2/</guid>

					<description><![CDATA[<p>MCB 97T3 MESUREUR DE CONCENTRATION HÉLIUM &#38; ARGON CATHAROMÈTRE HÉLIUM &#38; ARGON Le MCB 97T3 est un mesureur de concentration type catharomètre pour l&#8217;Hélium et l&#8217;Argon, mesure des concentrations des mélanges de gaz binaires ou pseudo binaires de 0.1% à 100%. Dans la même gamme : Pour une mesure de concentration ponctuel Hélium ou Argon [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/produits/mcb97/">MCB 97T3</a> est apparu en premier sur <a href="https://www.sapre.fr">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="6317" class="elementor elementor-6317" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-6e1a2b8 e-flex e-con-boxed e-con e-parent" data-id="6e1a2b8" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-508674c elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="508674c" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>MCB 97T3</h1>
<h2>MESUREUR DE CONCENTRATION HÉLIUM &amp; ARGON</h2>
<h2>CATHAROMÈTRE HÉLIUM &amp; ARGON</h2>
Le MCB 97T3 est un mesureur de concentration type catharomètre pour l&rsquo;Hélium et l&rsquo;Argon, mesure des concentrations des mélanges de gaz binaires ou pseudo binaires de 0.1% à 100%.

<h3>Dans la même gamme :</h3>
<p>Pour une mesure de concentration ponctuel Hélium ou Argon en usage portable, le <a href="https://www.sapre.fr/produits/tgdisplay/">TG DISPLAY</a> est le mesureur catharomètre portable dédié, principalement utilisé en technique de détection « sous enveloppe ».</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-a22ad72 e-flex e-con-boxed e-con e-parent" data-id="a22ad72" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-91a89cd e-con-full e-flex e-con e-child" data-id="91a89cd" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-9e79055 elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="9e79055" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 sur 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="9e79055" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTA1NSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL21jYjk3dDMtMS5qcGciLCJzbGlkZXNob3ciOiI5ZTc5MDU1In0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-1.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-1-768x768.jpg" alt="MCB 97T3 mesureur catharomètre Hélium Argon rack 19 pouces - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 sur 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="9e79055" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTA1NiwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL21jYjk3dDMtMi5qcGciLCJzbGlkZXNob3ciOiI5ZTc5MDU1In0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-2.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/mcb97t3-2-768x768.jpg" alt="" /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-left" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z"></path></svg>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-right" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z"></path></svg>					</div>
				
									</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d89a1ba e-con-full e-flex e-con e-child" data-id="d89a1ba" data-element_type="container">
				<div class="elementor-element elementor-element-2a2700d elementor-widget elementor-widget-text-editor" data-id="2a2700d" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Lecture de concentration de 0.1% à 100%.</li><li>Cellule de mesure à conductivité thermique insaturable ATEX.</li><li>Rack 19&Prime;, 21TE</li><li>Afficheur digital 3 chiffres.</li></ul><p><strong>Calibration :</strong></p><ul><li>Appareil pré-calibré pour l’hélium.</li><li>Autres calibrations possibles sur demande.</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-cb11727 elementor-widget elementor-widget-button" data-id="cb11727" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/demande-dinformations/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">DEMANDE D'INFORMATIONS</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-3ec9315 e-flex e-con-boxed e-con e-parent" data-id="3ec9315" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-ea1471b elementor-widget elementor-widget-text-editor" data-id="ea1471b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Fonctions</strong></td><td style="text-align: left;"><p>Tiroir rack 19’’, 3U, 21TE.</p><p>2 types de montage cellule (selon version) :</p><ul><li>Cellule déportée reliée par câble avec circulation du gaz par convection naturelle.</li><li>Cellule fixée à l’arrière du coffret avec coiffe et embouts pour le raccordement de tubes permettant l’alimentation en gaz.</li></ul></td></tr><tr><td style="text-align: left;"><strong>Affichage</strong></td><td style="text-align: left;"><p>Afficheur digital 3 chiffres.</p><p>Sortie analogique 0/1 volt.</p><p>2 relais de consignes [+] et [-] à seuil ajustable, avec sorties contacts T/R.</p></td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Cellule</strong></td><td style="text-align: left;">Cellule à conductibilité thermique insaturable ATEX.</td></tr><tr><td style="text-align: left;"><strong>Gaz détectés</strong></td><td style="text-align: left;">Calibration usine sur gaz Hélium,  autre gaz sur demande (Argon, &#8230;)</td></tr><tr><td style="text-align: left;"><strong>Sensibilité</strong></td><td style="text-align: left;">Lecture de concentration de 0.1% à 100%.</td></tr><tr><td style="text-align: left;"><strong>Autonomie</strong></td><td style="text-align: left;">n/a</td></tr><tr><td style="text-align: left;"><strong>Alimentation</strong></td><td style="text-align: left;">Alimentation secteur 220v, 50/60 Hz.</td></tr><tr><td style="text-align: left;"><strong>Livré avec</strong></td><td style="text-align: left;">Détecteur livré complet avec borniers enfichables à vis et notice d’emploi.</td></tr><tr><td style="text-align: left;"><strong>Option</strong></td><td style="text-align: left;">n/a</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/produits/mcb97/">MCB 97T3</a> est apparu en premier sur <a href="https://www.sapre.fr">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
