<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Calibrated Leak EN14624 | SAPRE</title>
	<atom:link href="https://www.sapre.fr/en/produits/calibrated-leak-en14624/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sapre.fr/en/produits/calibrated-leak-en14624/</link>
	<description>Conception et Fabrication de détecteurs de fuite de gaz</description>
	<lastBuildDate>Mon, 27 Apr 2026 14:31:27 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.5</generator>

<image>
	<url>https://www.sapre.fr/wp-content/uploads/2015/03/logo250-60x60.png</url>
	<title>Calibrated Leak EN14624 | SAPRE</title>
	<link>https://www.sapre.fr/en/produits/calibrated-leak-en14624/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FCE 99M-PVS-R</title>
		<link>https://www.sapre.fr/en/products/fce-99m-pvs-r/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 01 Apr 2014 10:01:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/?post_type=portfolio&#038;p=10476</guid>

					<description><![CDATA[<p>FCE 99M-PVS-R CALIBRATED LEAK EN14624 CALIBRATED LEAK R134a, R1234ze, R1234yf, R600a, R290 The FCE99M-PVS-R calibrated leak is intended for checking the sensitivity and calibration of construction site and production leak detectors operating by sniffing at atmospheric pressure according to the EN 14624 standard. In the same range: For an adjustable leak (rather than a fixed [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/en/products/fce-99m-pvs-r/">FCE 99M-PVS-R</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="10476" class="elementor elementor-10476" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-722f6fe e-flex e-con-boxed e-con e-parent" data-id="722f6fe" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-9b97027 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="9b97027" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>FCE 99M-PVS-R</h1>
<h2>CALIBRATED LEAK EN14624</h2>
<h2>CALIBRATED LEAK</h2>
<h2>R134a, R1234ze, R1234yf, R600a, R290</h2>
The FCE99M-PVS-R calibrated leak is intended for checking the sensitivity and calibration of construction site and production leak detectors operating by sniffing at atmospheric pressure according to the EN 14624 standard.

<h3>In the same range:</h3>
<p>For an adjustable leak (rather than a fixed value of 3 or 5 g/year), the <a href="https://www.sapre.fr/en/products/fce-24-pva-dr/">FCE 24-PVA-DR adjustable leak</a> features a built-in dual tank (expansion chamber + liquid gas reservoir) for HFC HFO HC refrigerant gases.</p>
<h3>Compatible with:</h3>
<p>The FCE 99M-PVS-R calibration leak compliant with the EN 14624 standard enables sensitivity testing of refrigerant gas detectors: <a href="https://www.sapre.fr/en/products/dxr-240/">DXR 240</a>, <a href="https://www.sapre.fr/en/products/hrd-92-sc/">HRD 92 SC</a> and <a href="https://www.sapre.fr/en/products/mtd-920/">MTD 920</a>.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-7767c72 e-flex e-con-boxed e-con e-parent" data-id="7767c72" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-8bab4d3 e-con-full e-flex e-con e-child" data-id="8bab4d3" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-135f85d elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="135f85d" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="135f85d" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTc3NywidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL2ZjZTk5bS1wdnMtci5qcGciLCJzbGlkZXNob3ciOiIxMzVmODVkIn0%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/fce99m-pvs-r.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/fce99m-pvs-r-768x768.jpg" alt="CE 99M-PVS-R fuite d&#039;étalonnage EN 14624 gaz réfrigérants - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="135f85d" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTc3OCwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL2ZjZTk5bS1wdnMtci1zaWRlLmpwZyIsInNsaWRlc2hvdyI6IjEzNWY4NWQifQ%3D%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/fce99m-pvs-r-side.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/fce99m-pvs-r-side-768x768.jpg" alt="CE 99M-PVS-R fuite d&#039;étalonnage EN 14624 gaz réfrigérants - SAPRE" /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-left" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z"></path></svg>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-right" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z"></path></svg>					</div>
				
									</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d681cc9 e-con-full e-flex e-con e-child" data-id="d681cc9" data-element_type="container">
				<div class="elementor-element elementor-element-2f7c4dd elementor-widget elementor-widget-text-editor" data-id="2f7c4dd" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Standard leak value of 3 g/year or 5 g/yr at gas vapor pressure at 20°C.</li><li>Designed to be supplied with gas in saturated vapor phase.</li><li>It has its own gas tank in liquid phase. SCHRADER type filling valve ¼ SAE male.</li><li>Delivered with a calibration certificate and a pressure-temperature/leakage flow correspondence curve.</li></ul><p><strong>Can be delivered for:</strong></p><ul><li>R134a, R1234ze, R1234yf, R600a, R290.</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-48e6356 elementor-widget elementor-widget-button" data-id="48e6356" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/en/information-request/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">INFORMATION REQUEST</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-f05c5c9 e-flex e-con-boxed e-con e-parent" data-id="f05c5c9" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-220c6ea elementor-widget elementor-widget-text-editor" data-id="220c6ea" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Use</strong></td><td style="text-align: left;">The FCE 99M-PVS-R leak is a continuous flow leak, it has its own gas reservoir in liquid phase. SCHRADER type filling valve ¼ SAE male.</td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Leak value</strong></td><td style="text-align: left;"><p>3 g/yr [+/-20%] at the vapor pressure of the gas at 20°C.</p><p>5 g/yr [+/-20%] at the vapor pressure of the gas at 20°C.</p><p>Other values, contact us.</p></td></tr><tr><td style="text-align: left;"><strong>Gas</strong></td><td style="text-align: left;"><p>R134a, R1234ze, R1234yf,&nbsp; R600a, R290.</p><p>Other gases contact us.</p></td></tr><tr><td style="text-align: left;"><strong>Delivred with</strong></td><td style="text-align: left;">Leak delivered with its calibration certificate valid for 1 year and a pressure-temperature/leak flow correspondence curve.</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/en/products/fce-99m-pvs-r/">FCE 99M-PVS-R</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FCH 99M-PVA-R150</title>
		<link>https://www.sapre.fr/en/products/fch-99m-pva-r150/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 01 Apr 2014 09:46:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/?post_type=portfolio&#038;p=10478</guid>

					<description><![CDATA[<p>FCH 99M-PVA-R150 ADJUSTABLE CALIBRATED LEAK WITH TANK Helium, Argon, H2/N2, H2, R32, CO2, SF6 The FCH99M-PVA-R150 adjustable calibrated leak is intended for sensitivity control and calibration of production and laboratory leak detectors operating by sniffing at atmospheric pressure. In the same range: For an adjustable leak supplied by an external bottle with pressure regulator (without [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/en/products/fch-99m-pva-r150/">FCH 99M-PVA-R150</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="10478" class="elementor elementor-10478" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-722f6fe e-flex e-con-boxed e-con e-parent" data-id="722f6fe" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-9b97027 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="9b97027" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>FCH 99M-PVA-R150</h1>
<h2>ADJUSTABLE CALIBRATED LEAK WITH TANK</h2>
<h2>Helium, Argon, H2/N2, H2, R32, CO2, SF6</h2>
The FCH99M-PVA-R150 adjustable calibrated leak is intended for sensitivity control and calibration of production and laboratory leak detectors operating by sniffing at atmospheric pressure.

<h3>In the same range:</h3>
<p>For an adjustable leak supplied by an external bottle with pressure regulator (without built-in tank), the <a href="https://www.sapre.fr/en/products/fch-99m-pva/">FCH 99M-PVA adjustable leak</a> is the alternative for HFC HFO HC refrigerant gases, as well as CO2, H2/N2, Helium and Argon.</p>
<h3>Compatible with:</h3>
<p>The FCH 99M-PVA-R150 adjustable calibrated leak enables sensitivity testing of multi-gas production detectors <a href="https://www.sapre.fr/en/products/mtd-920/">MTD 920</a> and <a href="https://www.sapre.fr/en/products/mtd-930/">MTD 930</a>, as well as the Helium and Argon leak detector <a href="https://www.sapre.fr/en/products/tg-expert/">TG EXPERT</a>.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-7767c72 e-flex e-con-boxed e-con e-parent" data-id="7767c72" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-8bab4d3 e-con-full e-flex e-con e-child" data-id="8bab4d3" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-135f85d elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="135f85d" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 1"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="135f85d" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6OTc5MSwidXJsIjoiaHR0cHM6XC9cL3d3dy5zYXByZS5mclwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDRcL2ZjaDk5bXItcHZhLmpwZyIsInNsaWRlc2hvdyI6IjEzNWY4NWQifQ%3D%3D" href="https://www.sapre.fr/wp-content/uploads/2024/04/fch99mr-pva.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2024/04/fch99mr-pva-768x768.jpg" alt="FCH 99M-PVA-R150 fuite calibrée ajustable réservoir intégré multi-gaz - SAPRE" /></figure></a></div>			</div>
					</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d681cc9 e-con-full e-flex e-con e-child" data-id="d681cc9" data-element_type="container">
				<div class="elementor-element elementor-element-2f7c4dd elementor-widget elementor-widget-text-editor" data-id="2f7c4dd" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Leak value adjustable in a value range depending on the applied pressure.</li><li>Designed to be supplied with gas in the “dry” vapor phase.</li><li>It has its own gas tank to fill in the “dry” vapor phase. 1/4FL filling needle valve.</li><li>Delivered with a calibration certificate and a pressure/leakage flow correspondence curve.</li></ul><p><strong>Can be delivered for:</strong></p><ul><li>Helium, Argon, H2/N2, H2, R32, CO2, SF6</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-48e6356 elementor-widget elementor-widget-button" data-id="48e6356" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/en/information-request/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">INFORMATION REQUEST</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-f05c5c9 e-flex e-con-boxed e-con e-parent" data-id="f05c5c9" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-220c6ea elementor-widget elementor-widget-text-editor" data-id="220c6ea" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><p><strong>Use</strong></p></td><td style="text-align: left;"><p>The FCH 99M-PVA-R150 leak is a continuous flow adjustable leak, it must be supplied with gas in the “dry” vapor phase.</p><p>It has its own gas tank to fill in the “dry” vapor phase. 1/4FL filling needle valve.</p></td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Leak value</strong></td><td style="text-align: left;"><p>Leak value adjustable between 1 g/yr and 10 g/year approximately [+/-20%] depending on the pressure applied.</p><p>The adjustment range depends on the version of the leak and the type of gas.</p><p>Other values, contact us.</p></td></tr><tr><td style="text-align: left;"><strong>Gas</strong></td><td style="text-align: left;"><p>Helium, Argon, H2/N2, H2, R32, CO2, SF6.</p><p>Other gases contact us.</p></td></tr><tr><td style="text-align: left;"><strong>Delivred with</strong></td><td style="text-align: left;">Leak delivered with its calibration certificate valid for 1 year and a leak pressure/flow correspondence curve.</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/en/products/fch-99m-pva-r150/">FCH 99M-PVA-R150</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FCE 24-PVA-DR</title>
		<link>https://www.sapre.fr/en/products/fce-24-pva-dr/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 01 Apr 2014 09:41:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.sapre.fr/?post_type=portfolio&#038;p=10480</guid>

					<description><![CDATA[<p>FCE 24-PVA-DR ADJUSTABLE CALIBRATED LEAK WITH TANK R134a, R1234ze, R1234yf, R32, R290, R600a The FCE24-PVA-DR adjustable calibrated leak is intended for sensitivity control and calibration of production and laboratory leak detectors operating by sniffing at atmospheric pressure according to the EN 14624 standard. In the same range: For a fixed-value leak (3 or 5 g/year) [&#8230;]</p>
<p>Cet article <a href="https://www.sapre.fr/en/products/fce-24-pva-dr/">FCE 24-PVA-DR</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="10480" class="elementor elementor-10480" data-elementor-post-type="portfolio">
				<div class="elementor-element elementor-element-722f6fe e-flex e-con-boxed e-con e-parent" data-id="722f6fe" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-9b97027 elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="9b97027" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h1>FCE 24-PVA-DR</h1><h2>ADJUSTABLE CALIBRATED LEAK WITH TANK</h2><h2>R134a, R1234ze, R1234yf, R32, R290, R600a</h2><p>The FCE24-PVA-DR adjustable calibrated leak is intended for sensitivity control and calibration of production and laboratory leak detectors operating by sniffing at atmospheric pressure according to the EN 14624 standard.</p><h3>In the same range:</h3><p>For a fixed-value leak (3 or 5 g/year) compliant with the EN 14624 standard, the <a href="https://www.sapre.fr/en/products/fce-99m-pvs-r/">FCE 99M-PVS-R calibration leak</a> is the dedicated alternative for certification, with its built-in tank for refrigerant gases R134a, R1234ze, R1234yf, R600a, R290.</p><h3>Compatible with:</h3><p>The FCE 24-PVA-DR adjustable calibrated leak enables sensitivity testing of refrigerant gas detectors: <a href="https://www.sapre.fr/en/products/dxr-240/">DXR 240</a>, <a href="https://www.sapre.fr/en/products/hrd-92-sc/">HRD 92 SC</a>, <a href="https://www.sapre.fr/en/products/mtd-920/">MTD 920</a> and <a href="https://www.sapre.fr/en/products/mtd-930/">MTD 930</a>.</p>						</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-7767c72 e-flex e-con-boxed e-con e-parent" data-id="7767c72" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-8bab4d3 e-con-full e-flex e-con e-child" data-id="8bab4d3" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-135f85d elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel" data-id="135f85d" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-carousel-wrapper swiper" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="polite">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 3"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="135f85d" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTIwOTQsInVybCI6Imh0dHBzOlwvXC93d3cuc2FwcmUuZnJcL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjZcLzA0XC9mY2UyNC1wdmEtZHIuanBnIiwic2xpZGVzaG93IjoiMTM1Zjg1ZCJ9" href="https://www.sapre.fr/wp-content/uploads/2026/04/fce24-pva-dr.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2026/04/fce24-pva-dr-768x768.jpg" alt="FCE 24-PVA-DR fuite d&#039;étalonnage EN 14624 ajustable gaz réfrigérants - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 of 3"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="135f85d" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTIwOTUsInVybCI6Imh0dHBzOlwvXC93d3cuc2FwcmUuZnJcL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjZcLzA0XC9mY2UyNC1wdmEtZHJfbGVmdC5qcGciLCJzbGlkZXNob3ciOiIxMzVmODVkIn0%3D" href="https://www.sapre.fr/wp-content/uploads/2026/04/fce24-pva-dr_left.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2026/04/fce24-pva-dr_left-768x768.jpg" alt="FCE 24-PVA-DR fuite d&#039;étalonnage EN 14624 ajustable gaz réfrigérants - SAPRE" /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="3 of 3"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="135f85d" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTIwOTYsInVybCI6Imh0dHBzOlwvXC93d3cuc2FwcmUuZnJcL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjZcLzA0XC9mY2UyNC1wdmEtZHJfcmlnaHQuanBnIiwic2xpZGVzaG93IjoiMTM1Zjg1ZCJ9" href="https://www.sapre.fr/wp-content/uploads/2026/04/fce24-pva-dr_right.jpg"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://www.sapre.fr/wp-content/uploads/2026/04/fce24-pva-dr_right-768x768.jpg" alt="FCE 24-PVA-DR fuite d&#039;étalonnage EN 14624 ajustable gaz réfrigérants - SAPRE" /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-left" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z"></path></svg>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<svg aria-hidden="true" class="e-font-icon-svg e-eicon-chevron-right" viewBox="0 0 1000 1000" xmlns="http://www.w3.org/2000/svg"><path d="M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z"></path></svg>					</div>
				
									</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d681cc9 e-con-full e-flex e-con e-child" data-id="d681cc9" data-element_type="container">
				<div class="elementor-element elementor-element-2f7c4dd elementor-widget elementor-widget-text-editor" data-id="2f7c4dd" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<ul><li>Leak value adjustable in a value range depending on the applied pressure.</li><li>Designed to be supplied with gas in the “dry” vapor phase.</li><li>It has a double tank: an expansion chamber and a gas tank to be filled with gas in the liquid phase. SCHRADER type filling valve ¼ SAE male.</li><li>Delivered with a calibration certificate and a pressure/leakage flow correspondence curve.</li></ul><p><strong>Can be delivered for:</strong></p><ul><li>R134a, R1234ze, R1234yf, R32, R290, R600a</li></ul>						</div>
				</div>
				<div class="elementor-element elementor-element-48e6356 elementor-widget elementor-widget-button" data-id="48e6356" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
					<div class="elementor-button-wrapper">
			<a class="elementor-button elementor-button-link elementor-size-sm" href="https://www.sapre.fr/en/information-request/">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">INFORMATION REQUEST</span>
					</span>
					</a>
		</div>
				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-f05c5c9 e-flex e-con-boxed e-con e-parent" data-id="f05c5c9" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-220c6ea elementor-widget elementor-widget-text-editor" data-id="220c6ea" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<table class="tableprod"><tbody><tr><td style="text-align: left;"><strong>Use</strong></td><td style="text-align: left;"><p>La fuite FCE 24-PVA-DR est une fuite ajustable à débit continue, elle doit être alimentée en gaz en phase vapeur « sèche ».</p><p>Elle est possède un double réservoir : une chambre de détente  et un réservoir de gaz à remplir en phase liquide. Vanne de remplissage type SCHRADER 1/4FL.</p></td></tr></tbody><tbody><tr><td style="text-align: left;"><strong>Leak value</strong></td><td style="text-align: left;"><p>Valeur de fuite ajustable entre 1 g/an et 5 g/an environ [+/-20%] selon la pression appliqué.</p><p>La plage d’ajustement dépendant de la version de la fuite et du type de gaz.</p><p>Autres valeurs nous consulter.</p></td></tr><tr><td style="text-align: left;"><strong>Gas</strong></td><td style="text-align: left;"><p>R134a, R1234ze, R1234yf, R32, R290, R600a.</p><p>Autres gaz nous consulter.</p></td></tr><tr><td style="text-align: left;"><strong>Delivred with</strong></td><td style="text-align: left;">Leak delivered with its calibration certificate valid for 1 year and a leak pressure/flow correspondence curve.</td></tr></tbody></table>						</div>
				</div>
					</div>
				</div>
				</div>
		<p>Cet article <a href="https://www.sapre.fr/en/products/fce-24-pva-dr/">FCE 24-PVA-DR</a> est apparu en premier sur <a href="https://www.sapre.fr/en/home/">SAPRE</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
